- Home
- >
- Glass Reactors
- >
- Jacketed Glass Reactors
- >
- EHANOL EXTRACTION AND WINTERIZATION REACTOR SYSTEM
EHANOL EXTRACTION AND WINTERIZATION REACTOR SYSTEM
20L Ethanol Reactor Base System 20 liter jacketed reactor base system designed specifically to operate at the extremely low temperatures required to perform ethanol extraction and winterization. Contact our technical support staff to choose a chiller with the appropriate connections, explosion proof motor and any other accessories needed
20L Ethanol Reactor Base System 20 liter jacketed reactor base system designed specifically to operate at the extremely low temperatures required to perform ethanol extraction and winterization. Contact our technical support staff to choose a chiller with the appropriate connections, explosion proof motor and any other accessories needed
Be the first to review “EHANOL EXTRACTION AND WINTERIZATION REACTOR SYSTEM” Cancel reply
Related Products
PHOTOBIOLOGICAL-OXIDATION APPARATUS 1200W, U.V.
Standard unit for liberation of inorganic phosphate from organically bound phosphorus compounds, oxidation of carbon inorganic matter and oxidation of organic nitrogen compounds. Oxidation of organic compounds in water and sediment samples is accomplished by exposure to ultraviolet radiation in the presence of excess oxygen. Organically bound phosphorus is liberated as the ortho-phosphate in as little as one hour. Organic matter is oxidized to CO2. Nitrogen compounds are oxidized to the nitrate and nitrite ions.
Additional applications include decomposition of organometallic compounds, providing organic-free samples for culture, nutrition and vitamin assay, destruction of algal suspensions, and oxidation of sediment or residue samples.
Apparatus consists of a cylindrical lamp housing with twelve-position sample tube chamber for twelve quartz tubes of approximately 100mL capacity that surround a 1200 watt medium pressure photochemical lamp. Access door is provided for set-up, inspection and repairs only — for your safety, do not use this door while the unit is in operation.
A cooling fan is located at bottom of housing for air movement. Lamp power supply includes a manual or automatic twelve-hour timer selector for programming exposure time. Available in 220v, 60Hz or 230v, 50Hz. Lamp housing measures 12” wide x 20” deep x 36” high, and weighs 75lbs. Power supply measures 11” wide x 18” deep x 11” high, and weighs approximately 75lbs.
GLASS REACTORS CYLINDRICAL UN JACKETED KIL0 SCALE COOLING AND HEATING 200L
200L Reactors w/Support Stand: Black epoxy-coated aluminum flask support plate is adjustable vertically, to allow room under flask for various outlet receptacles. Plate is supplied with three adjustable braces to hold mantle in place. Upper support brackets supplied to stabilize flask.
Unjacketed Kilo Systems include:
• 4 Post Reactor Stand
• Unjacketed Flask
• Head, Coupling and O-Rings
• Agitator, Stir Shaft, Bearing & Collar
• Lid and Clamp
• Bottom Drain Valve
• Heating Mantle
• Temperature Controller with Pr
REACTION SYSTEM #50 Ace-Thred, 450W
Complete reaction assembly with all parts needed for immediate operation. Utilizes an internally threaded connection in place of the ground glass joint. Bushing and FETFE O‑Ring form a compression type seal with immersion well. Well has removable inner cooling tube. Reactor has (1) 14/20 angled joint for sparger tube, (1) 24/40 vertical joint for condenser, and (1) #7 Ace-Thred for thermometer. Volume indicated is total volume. Actual working volume is approximately 40-50% of total.
REACTION SYSTEM Standard Taper, 450W
Complete reaction assembly with all parts needed for immediate operation. Borosilicate glass reactor has a 60/40 center joint, (1) 14/20 angled joint for sparger tube, (1) 24/40 vertical joint for condenser, and (1) #7 Ace-Thred joint to accommodate thermometer. Volumes indicated are total volumes. Volume in reactive area of lamp is 40-50% of the total volume.
➧➧Rugged, steel-reinforced PTFE stirring rod
➧➧Heavy duty mechanical lab stirrer
➧➧Temperature controlled heating mantle
Complete reaction assembly using standard ACE reaction equipment. The 12L through 72L flasks have three 65/40 in-line spherical joints and two 29/42 standard taper joints.
Features
• Full range of pilot-size flasks from 12L to 72L with spherical and standard taper joints.
• Rugged 19mm diameter, steel-reinforced PTFE stirring rod needs no lubrication. Runs in a precision Trubore™ bearing. The PTFE paddle is removable, and other interchangeable agitators available from ACE may be substituted.
• The 12L assembly has a 10mm diameter steel-reinforced PTFE rod, as well as a 10mm bearing, chuck, and paddle.
• Highly efficient 6016 condenser is attached directly to 65/40 side joint.
• Thermowell depth is completely adjustable via an Ace‑Thred adapter.
• Unit as supplied has a heavy-duty mechanical lab stirrer; for situations that call for nonelectric motors, ACE can supply a compact air-driven motor and support. Call or e-mail for a quotation.
• Heavy-duty bottom heating mantle.
• Approximate overall height: 12L and 22L – 59”; 50L and 72L – 63”
GLASS REACTORS UN JACKETED BENCH TOP 100ML ,250ML, 500ML, 1L, 2L,3L, 5L 6L
Ace Glass Scale-Up Series™ reactor systems enable the researcher to scale-up from 100mL to 6000mL on the bench and enjoy the same geometry when replicating those results in our Kilo Scale reactors. Simply select the capacity you desire in the base system seen below. Complete your system with any of the many optional components we offer.
Scale-Up Systems include:
• Single Reactor Stand
• Bolt Latch Clamp
• Support Ring
• Unjacketed Flask with O-Ring and Cla
PHOTOBIOLOGICAL-OXIDATION APPARATUS 1200W, U.V., Flow-Thru
Modified version of 7900 Apparatus. Sample tubes have been replaced with a flow-thru quartz or borosilicate coil for continuous radiation of small (as little as 175mL) or large samples. Coil is available with cooling jacket for slow flow rates or without jacket when heating of sample is not a concern because of the higher flow rate.
Apparatus consists of a cylindrical lamp housing, medium pressure 1200 watt photochemical lamp, quartz or borosilicate glass coil (with or without jacket), and power supply. Access door is provided for set-up, inspection and repairs only — for your safety, do not use this door while the unit is in operation.
A cooling fan is located at bottom of housing for air movement. Lamp power supply includes a manual or automatic twelve-hour timer selector for programming exposure time. Available in 220v, 60Hz or 230v, 50Hz. Lamp housing measures 12” wide x 20” deep x 36” high, and weighs 75 lbs. Power supply measures 11” wide x 18” deep x 11” high, and weighs approximately 75 lbs. Coil is 12.7mm O.D. x 8.0mm (5/16”) I.D. with 1/2” Swagelok ends, 16 ±1 turns with approximate capacity of 175mL, maximum flow rate of 10L/min.
Reviews